Sign In | Join Free | My burrillandco.com
Home > MPPT VFD Solar Pump Inverter >

MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad

Shenzhen ZK Electric Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad from wholesalers
     
    Buy cheap MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad from wholesalers
    • Buy cheap MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad from wholesalers
    • Buy cheap MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad from wholesalers

    MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad

    Ask Lasest Price
    Brand Name : ZK/ZUN
    Model Number : SU10M-D2-2R2G-B
    Certification : ISO CE
    Price : Negotiable
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 6000 units per month
    Delivery Time : 3-7 working days
    • Product Details
    • Company Profile

    MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad

    ZK/ZUN Solar VFD 0.75kw 2.2kw 450VDC 220VAC LED Keypad MPPT Vfd Solar Pump Inverter


    SU10M-D2-2R2G-B mini size 2.2kw solar pump inverter


    Quick Details:


    1.Adopt advanced MPPT technology to give full play to the power generation efficiency of the solar cell array;
    2.Automatically adjust the motor speed and the water output of the water pump according to the change of sunlight intensity;
    3.The inverter automatically sleeps when the water level of the reservoir is high, and restarts automatically when the water level is low, realizing automatic water level control;
    4.It can prevent the water pump from dry pumping without water when the water source is dry;
    5.When the light is weak (such as the sun sets), it will automatically sleep, and when the light becomes strong (such as sunrise), it will exit the sleep;


    Features:

    1.Energy saving and environmental protection
    2.Plastic shell and sheet metal shell design



    ItemSpecification
    Power inputVoltage, frequencyDI: 70V DC to 400V DC or 110V±15% AC, 50/60Hz S
    D2: 150V DC to 450V DC or 220V±15% AC, 50/60Hz;
    D3: 350V DC to 750V DC or 380V±15% AC, 50/60Hz
    Allowable fluctuationsvoltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required
    Power factor≥0.94(with DC reactor)
    Mppt Efficiency≥99.6%
    OutputOutput voltageOutput under rated condition: 3 phase, 0~input voltage, inaccuracy<5%
    Output frequency rangeG type:0~600Hz
    Output frequency accuracyMax frequency ±0.5%
    Overload capacityG type: 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s
    Motor control modeV/F without PG , VC without PG , VC with PG
    Product basic functionsAcceleration/Deceleration curve2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration.
    4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s.
    Rated output voltageRely on power supply voltage compensate function, while motor rated voltage is 100%, set it at the range of 50-100%(output can not over input voltage).
    Voltage auto-adjustmentWhile power supply voltage fluctuates, it can auto-keep constant output voltage.
    Auto energy-saving runningWhile under V/F control mode, according to load situation, auto-optimize output voltage to save energy.
    Standard functionsPID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output.
    Frequency setting channelsKeyboard digital setting, keyboard potentiometer ,Analog voltage/current terminal AI1,AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch.
    Feedback input channelVoltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication
    given, pulse input X5.
    Running command channelOperation panel given,external terminal given, communication given, expansion card given.
    Input command signalStart, stop, FWD/REV, JOG, multi-step speed, reset, ACC/DEC time selection, frequency given channel selection, exterior fault alarm.
    Protective functionOvervoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection.
    EnvironmentInstall placealtitude ≤ 1000m,above 1000m down the rated amount, each increase of 100m down the rated mount of 1%;no condensation, ice ,rain, snow, hail; solar radiation below 700W/㎡, air pressure 70-106 kPa.
    Temperature, humidity-10 ~ + 50 ℃, derating above 40 ℃, maximum temperature 60 ℃ (no-load operation)5% to 95% RH (non-condensing)
    VibrationWhen 9~200Hz, 5.9m/s2(0.6g)
    Storage temperature-30 ~+60℃
    Protection gradeIP20
    Cooling methodForced air cooling

    Model List:


    MODELSRate current (A)Applicable for pumps

    Input Voltage

    Range DC (V)

    Output voltage
    VAC
    General type D1:90V DC to 400V DC or 110V±15% AC Input, 50/60Hz, 3 Phase 0-110Vac ouptut
    SU10M-D1-R75G-B7A0.75kw70-400V0-110V
    SU10M-D1-1R5G-B10A1.5kw70-400V0-110V
    General type: D2:150V DC to 450V DC or 220V±15% AC Input, 50/60Hz, 3 Phase 0-220Vac ouptut
    SU10M-D2-R75G-B4A0.75kw150-450V0-220V
    SU10M-D2-1R5G-B7A1.5kw150-450V0-220V
    SU10M-D2-2R2G-B10A2.2kw150-450V0-220V
    SU10M-D2-004G-B16A4.0kw150-450V0-220V
    General type: D3:250V DC to 800V DC or 380V±15% AC input, 50/60Hz, 3 Phase 0-380V/440Vac ouptut
    SU100-D3-R75G-B3A0.75kw250-800V0-380V/440V
    SU100-D3-1R5G-B4A1.5kw250-800V0-380V/440V
    SU100-D3-2R2G-B6A2.2kw250-800V0-380V/440V
    SU100-D3-004G-B9.2A4.0kw250-800V0-380V/440V
    SU100-D3-5R5G-B13A5.5kw250-800V0-380V/440V
    SU100-D3-7R5G-B17A7.5kw250-800V0-380V/440V
    SU100-D3-011G-B25A11kw250-800V0-380V/440V
    SU100-D3-015G-B32A15kw250-800V0-380V/440V
    SU100-D3-018G-B37A18.5kw250-800V0-380V/440V
    SU100-D3-022G-B45A22kw250-800V0-380V/440V
    SU100-D3-030G60A30kw250-800V0-380V/440V
    SU100-D3-037G75A37kw350-800V0-380V/440V
    SU100-D3-045G90A45kw350-800V0-380V/440V
    SU100-D3-055G112A55kw350-800V0-380V/440V
    SU100-D3-075G150A75kw350-800V0-380V/440V

    Inverter modelDimensions(mm)Installation(mm)Mounting aperture
    WHDD1W1H1
    SU100-D1-R75G-B8919013514479180M4×2
    SU100-D2-R75G-B
    SU100-D2-1R5G-B
    SU100-D3-R75G-B
    SU100-D3-1R5G-B
    SU100-D3-2R2G-B
    SU100-D1-1R5G-B10623014815796219M4×3
    SU100-D2-2R2G-B
    SU100-D2-004G-B
    SU100-D3-004G-B
    SU100-D3-5R5G-B
    SU100-D3-7R5G-B
    SU100-D3-011G-B130275160169115260M5×3
    SU100-D3-015G-B
    SU100-D3-018G-B155335191200141.5320M5×4
    SU100-D3-022G-B

    ---FAQ---

    Q1 : What's the different between inverter and solar inverter?
    Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accpet DC input, it more save power.


    Q2: What should be noticed when installing inverter?
    Put the product in a place where is well ventilate,cool, dry and water-proof. Do not stress or put foreign objects into the inverter. Remember to turn on the inverter before turn on the appliance.



    Q3:What is the payment terms?
    100% T/T in advance for sample order. 30% T/T in advance, banlance 70% T/T before delivery for bulk order.


    Q4:What is your main market?
    Our brands are well known in Europe, Africa, Middle East, Southeast Asia and South America.


    Q5 : How about the delivery time?
    3-5 days for sample order;15-25 days for bulk order.


    Q6:What is the supply capacity of your factory?
    The monthly output of inverters is over 6,000 units.
    For regular orders, we can deliver to you in 5-24 days.


    Quality MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen ZK Electric Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)